236   Direct a.c. frequency converters

                           3 phase
                           double star
                           a.c.  supply







                                                                             point



























                        Fiapre 10.18 Push-pull six-pulse cycloconverter with circulating current limiting reactor

                        greater extent.  If  p is the pulse number  of  the converter system,  V the
                         r.m.s.  supply voltage to the cycloconverter, and X the effective source
                         reactance, then the circulating current (i,) is limited to the value given by
                         equation (10.1).

                                                                                   (10.1)
                          An alternative method for suppressing the flow of  circulating current is
                        to ensure that only one converter conducts at any time. This is by far the
                        most  satisfactory  arrangement,  since  the  circulating currents can  often
                        become  extremely  large,  but  it  does  result  in  a  much  more  complex
                        thyristor control system in which the load current must be sensed and used
                        to  block  one  or  other  group  of  converter,  depending  on  the  current
                        direction.  Another  disadvantage of  the  non-circulating current  mode  is
                        that the load voltage distortions can become much higher on light loads,
                        when the current becomes discontinuous. Since discontinuous operation is
                        only  serious  on  light  loads,  it  is  feasible  to  run  a  cycloconverter in  a
                        circulating-current mode when the load current falls below a certain critical