Page 221 - Reciprocating Compressors Operation Maintenance
P. 221

Operation and Maintenance  of  Reciprocating  Compressors  2O7





































         FIGURE   3-62.  Reverse  flow  unloading  device  in  suction  passage of a
         compressor  cylinder  (Source:  Hoerbiger  Corporation  of  America,  Pompano
         Beach,  Florida).


           Figure  3-62  shows this control  in the  suction passage  of a  compressor
         cylinder,

         MAINTENANCE    OF COMPRESSOR   CONTROLS

           Compressor  control  systems  that have  been  properly  set  initially are
         generally  trouble-free  and require little maintenance.  Probably  the great-
         est problems are caused  by dirt and moisture entering  the pneumatic  sys-
         tem  and  plugging orifices.  It  is,  therefore,  important to  maintain and
         change any strainers and filters that are included in the system.
           Table  3-12  represents  an  operation  chart  for  a  two-stage  compressor
         equipped  with five-step  control.  It  includes  checks  to  assist  in  trou-
         bleshooting.
   216   217   218   219   220   221   222   223   224   225   226