Page 223 - Reciprocating Compressors Operation Maintenance
P. 223

TABLE 3- 12
 OPERATION CHART FOR TWO-STAGE COMPRESSOR WITH FIVE-STEP CONTROL
 Load Position    Trouble Checks
          Low                     High
 Lights   Capacity   Operation   Intercooler Pressure   Intercooler Pressure

 No Lights   Zero   All suction valves held open   High pressure discharge
 Clearance pockets closed    valves faulty
                             (Pressure continues to
                             build up)
 One Light   25 %   Head end suction valves held   Crank End   Crank End
 open   Low pressure discharge   High pressure suction
 Crank end suction valves closed   valves faulty   valves faulty or
 Clearance pockets open   Crank End   unloader stuck open
     Low pressure suction    Crank End
     valves faulty or unloader   High pressure discharge
     stuck open              valves faulty
 Two Lights   50%   Head end suction valves   Head End
 closed   Low pressure discharge   Head End
 Crank end suction valves   valves faulty   High pressure suction
 held open   Head End        valve faulty or unloader
 Clearance pockets closed   Low pressure suction   stuck open
     valves faulty or un-    Head End
     loader stuck open       High pressure discharge
                             valve faulty
 Three Lights   75%   Head end suction valves   If low also at 25%   If high also at 25% but
 closed   capacity but good at   good at 50%, same check as
 Crank end suction valves   5096, same check as for   for 25% capacity
 closed   25% capacity       If good at 25%  but high
 Clearance pockets open   If good at 25% but low   at 50% also, same check as
     at 50% also same check   for 50% capacity
     as for 50% capacity
 Four Lights   100%   Head end suction valves   If also low at 25% and   If also high at 25% and 75% but
 closed   75% capacity but   good at 50%, same check as
 Crank end suction valves   good at 5096, same check   for 25%
 closed   as 25%             If also high at 50% and 75%
 Clearance pockets closed   If also low at 50% and   same check as for 50%
     7596, same check as for   If high also at 50% only,
     25%                     same check as for 50%
     If low also at 50% only,
     same check as for 50%
 Note: Faulty valves refer to incorrect installation, bad gaskzt, or broken strips.