Page 222 - Reciprocating Compressors Operation Maintenance
P. 222

TABLE 3- 12
                         OPERATION CHART FOR TWO-STAGE COMPRESSOR WITH FIVE-STEP CONTROL
                                   Load Position                                   Trouble Checks
                                                                           Low                     High
                  Lights    Capacity      Operation                   Intercooler Pressure    Intercooler Pressure

                 No Lights     Zero       All suction valves held open                        High pressure discharge
                                          Clearance pockets closed                            valves faulty
                                                                                              (Pressure continues to
                                                                                              build up)
                 One Light     25 %       Head end suction valves held   Crank End            Crank End
                                          open                        Low pressure discharge   High pressure suction
                                          Crank end suction valves closed   valves faulty     valves faulty or
                                          Clearance pockets open      Crank End               unloader stuck open
                                                                      Low pressure suction    Crank End
                                                                      valves faulty or unloader   High pressure discharge
                                                                      stuck open              valves faulty
                 Two Lights    50%        Head end suction valves     Head End
                                          closed                      Low pressure discharge   Head End
                                          Crank end suction valves    valves faulty           High pressure suction
                                          held open                   Head End                valve faulty or unloader
                                          Clearance pockets closed    Low pressure suction    stuck open
                                                                      valves faulty or un-    Head End
                                                                      loader stuck open       High pressure discharge
                                                                                              valve faulty
                 Three Lights   75%       Head end suction valves     If low also at 25%      If high also at 25% but
                                          closed                      capacity but good at    good at 50%, same check as
                                          Crank end suction valves    5096, same check as for   for 25% capacity
                                          closed                      25% capacity            If good at 25%  but high
                                          Clearance pockets open      If good at 25% but low   at 50% also, same check as
                                                                      at 50% also same check   for 50% capacity
                                                                      as for 50% capacity
                 Four Lights   100%       Head end suction valves     If also low at 25% and   If also high at 25% and 75% but
                                          closed                      75% capacity but        good at 50%, same check as
                                          Crank end suction valves    good at 5096, same check   for 25%
                                          closed                      as 25%                  If also high at 50% and 75%
                                          Clearance pockets closed    If also low at 50% and   same check as for 50%
                                                                      7596, same check as for   If high also at 50% only,
                                                                      25%                     same check as for 50%
                                                                      If low also at 50% only,
                                                                      same check as for 50%
                Note: Faulty valves refer to incorrect installation, bad gaskzt, or broken strips.