Page 180 - Shale Shakers Drilling Fluid Systems
P. 180

SOLIDS CONTROL EQUIPMENT  163



        motor) or a single diesel engine for each pump.       would allow operators to pump from anywhere to
        Manifolding of suction or discharge lines rarely re-  anywhere with any pump. However, leaky and im-
        sults in effective equipment performance. Funds       properly aligned valves can destroy removal effi-
        normally used for valves in a "do-anything" man-      ciency. For example, a system operating at 90%
        ifold, should be used to store an extra pump          drilled solids removal efficiency can quickly deterio-
        and motor in case of failure. Pumps and motors        rate to 40% efficiency with only two valves improp-
        should be mounted so that they are easy to install    erly set. If the target drilled solids concentration is
        and maintain.                                         8% volume or less, the low drilled solids removal
          Unfortunately, the above suggestions create a       efficiency can easily require two to four times as
        great deal of controversy. Ideally, the fluid system  much drilling fluid to drill a well (see Chapter 8).
   175   176   177   178   179   180   181   182   183   184   185