Reaction vs. Impulse Type Steam Turbines  239





























            Figure 12.17 Water-steam mixing arrangement used in low-speed water
            wash systems. (Dresser-Rand Company, Wellsville, N.Y.)

              The washing may be continued until conductivity measurements of
            the condensate or exhaust steam indicate that no further deposits are
            being dissolved. Additionally, it is appropriate to note that the trip-
            throttle valve should be checked to be certain it is operating satisfacto-
            rily since washing may not thoroughly clean deposits from this valve
            and that if carryover deposits are not also cleaned from the piping
            between the boiler and the turbine, this carryover may be deposited in
            the turbine in a very short period after washing.




















            Figure 12.18 Full-speed water wash arrangement. (Dresser-Rand Company, Wells-
            ville, N.Y.)