Table 7.2 Suggested welding parameters – argon shielding

 Thickness  Root gap/  Included angle  Backing  Current  Voltage  No. of  Filler diam.  Travel speed
 (mm)  face (mm)  (degrees)  (A)  (V)  passes  (mm)  (mm/min)

 1.6  nil  Square  Temporary  100  19  1  0.6  1000
 2.5  Square  Permanent  100  19  1  0.6      1000
 2.4  nil  Square  Temporary  140  21  1  0.6  1000
 3.2  Square  Permanent  130  23  1  0.6      780
 3.2  2.5  Square  Temporary  160  24  1  1.2  780
 5  Square  Permanent  135  23  1  1.2        720
 4  1.5  Square  None  170  26  1 face  1.2   750
                      1 reverse
 1.5/2.5  60  Temporary  160  27  1  1.2      750
 single-V
 4.5/1.5  60  Permanent  185  27  2  1.6      750
 single-V
 6.3  2.5  Square  None  200  28  1 face  1.6  750
                      1 reverse
 2.5/2.5  60  Temporary  185  27  2  1.6      750
 single-V
 6/1.5  60  Permanent  225  29  3  1.6        750
 single-V
 8  2.5/1.5  60  Temporary  245  29  2  1.6   750
 single-V
 4.5/nil  60  Permanent  255  29  3  1.6      750
 single-V
 10  2.5/4.5  90  None  290  29  1 face  1.6  750
 single-V             1 reverse
 2.5/2.5  60  Temporary  275  29  2 face  1.6  900
 single-V             1 reverse
 4.5/nil  60  Permanent  275  26  3  1.6      800/550
 single-V