Design of experimental liquid-metal facilities                     87

              Thermal power of 1MW. A fuel pin simulator consisting of an electrically heated pin bundle
           l
              is adopted for this aim.
              An innovative steam generator bayonet tube bundle is adopted as heat sink, named heavy
           l
              liquid mrtal-pressurized water cooled tube (HERO), which adopts pressurized water as sec-
              ondary coolant.
           Concerning the flow path here conceptualized (see Fig. 3.2.1), LBE flows through the
           fuel pin simulator moving upward and then through the riser, in which gas is injected
           to promote gas-enhanced circulation; reaches the separator in the upper part; and
           moves downward through the steam generator (HERO). This requirement is typical
           for almost any heavy liquid-metal pool-type reactor.












                                             HERO
                                             steam generator



                                             Riser
                          Dead
                          volume




                      Fitting
                      volume
                                               Fuel pin
                                               simulator





                        Feeding
                        conduit






           Fig. 3.2.1 Main flow path.