Page 424 - Materials Chemistry, Second Edition
P. 424

CAT3525_C12.qxd  1/27/2005  4:11 PM  Page 395
                       Hazardous Waste Generator Requirements                                      395

                       TABLE 12.3
                       Typical Hazardous Waste Generated by Small-Quantity Generators

                       Typical Type of Business   How Generated     Types of Wastes      Waste Codes
                       Dry cleaning and    Commercial dry cleaning   Still residues from solvent   D001, D039, F002
                        laundry plants      processes                 distillation, spent filter
                                                                      cartridges, cooked powder
                                                                      residue
                       Furniture/Wood      Wood cleaning and wax    Ignitable wastes, toxic   D001, F001–F005
                        manufacturing and   removal, refinishing/stripping,  wastes, solvent wastes,
                        refinishing         staining, painting, finishing,  paint wastes
                                            brush cleaning and spray brush
                                            cleaning
                       Construction        Paint preparation and painting,  Ignitable wastes, toxic   D001, D0002
                                            carpentry and floor work, other   wastes, solvent wastes,  F001–F005
                                            speciality contracting activities,  paint wastes, used oil,
                                            heavy construction,       acids/bases
                                            wrecking and demolition,
                                            vehicle and equipment
                                            maintenance for construction
                                            activities
                       Laboratories        Diagnostic and other laboratory   Spent solvents, unused   D001, D002
                                            testing                   reagents, reaction products,  D003,
                                                                      testing samples,     F001–F005,
                                                                      contaminated materials  U211
                       Vehicle maintenance  Degreasing, rust removal, paint   Acids/bases, solvents,
                                            preparation, spray booth, spray   ignitable wastes, toxic   D001, D002,
                                            guns, brush cleaning,     wastes, paint wastes,  D006, D008,
                                            paint removal, tank cleanout,  batteries       F001–F005
                                            installing lead-acid batteries
                       Printing and allied   Plate preparation, stencil   Acids/bases, heavy-metal   D002, D006,
                        industries          preparation for screen printing,  wastes, solvents, toxic   D008,
                                            photo processing, printing,  wastes, ink       F001–F005
                                            clean-up
                       Equipment repair    Degreasing, equipment cleaning,  Acids/bases, toxic wastes,  D001, D002,
                                            rust removal, paint preparation,  ignitable wastes, paint   D006, D008,
                                            painting, paint removal, spray   wastes, solvents  F001–F005
                                            booth, spray guns, and brush
                                            cleaning
                       Pesticide end-      Pesticide application and   Used/unused pesticides,  D001, F001–F005,
                        users/application   clean-up                  solvent wastes, ignitable   U129,
                        services                                      wastes, contaminated soil   U136, P094,
                                                                      (from spills), contaminated   P123
                                                                      rinse water, empty
                                                                      containers
                       Educational and     Automobile engine and body   Ignitable wastes, solvent   D001, D002,
                        vocational shops    repair, metal working, graphic   wastes, acids/bases, paint   F001–F005
                                            arts-plate preparation,   wastes
                                            woodworking
                       Source: U.S. EPA, 2001b. With permission.
   419   420   421   422   423   424   425   426   427   428   429