Page 257 - Water and wastewater engineering
P. 257

6-34   WATER AND WASTEWATER ENGINEERING



















                            (a) Radial-flow turbine impeller      (b) Axial-flow impeller
                            FIGURE 6-18
                            Basic impeller styles. (Source: SPX Process Equipment.)

                            TABLE 6-5
                            Tank and impeller geometries for mixing

                             Geometric ratio          Range
                             D/T (radial)            0.14–0.5
                             D/T (axial)             0.17–0.4
                             H/D (either)              2–4
                             H/T (axial)             0.34–1.6
                             H/T (radial)            0.28–2
                             B/D (either)            0.7–1.6

                            D   impeller diameter
                                                                .
                                                          ⎛  4 A ⎞  0 5
                            T  equivalent tank diameter
                                                          ⎝    ⎠
                            A   the plan area
                            H   water depth
                            B   water depth below the impeller

                            deeper by using two impellers on the shaft. When dual impellers are used, the top impeller is
                            axial flow, while the bottom impeller is radial flow. When dual impellers are employed on gear-
                            driven mixers, they are spaced approximately two impeller diameters apart. We normally assume
                            an efficiency of transfer of motor power to water power of 0.8 for a single impeller.
                                  The power imparted to the liquid in a baffled tank by an impeller may be described by the
                            following equation for fully turbulent flow developed by Rushton (1952).

                                                                     3
                                                            P    N n () (  5                            (6-17)
                                                                  p
                                                                       Di)
                            where  P       power, W

                                      N    p        impeller constant (also called power number)
   252   253   254   255   256   257   258   259   260   261   262