2.6 QC IN DATA ACQUISITION                         135


                                                                                                 ☑
                             Parameter                           Planned         Configured
                             Low cut filter                      3 Hz/18 dB      3 Hz/18 dB      □
                             High cut filter                     200 Hz/210 dB   200 Hz/210 dB   □
                             Auxiliary channels                  60              60              □
           Sources           Number of sources                   2               2               □
                             Total gun volume per source         3090 in 3       3090 in 3       □
                             Number of subarrays                 3               3               □
                             Number of guns per subarray         8               8               □
                             Number of hydrophones per subarray  8               8               □
                             Number of depth transducers per subarray  4         4               □
                             Number of pressure sensors per subarray  1          1               □
                             Source depth                        6 m             6 m             □
                             Source separation                   50 m            50 m            □
                             Nominal air pressure                2000 psi        2000 psi        □
           Verifications
           Checking of recording system/streamer telemetry                                       □
           Performing a full recording system/streamer test                                      □
           Checking of trace polarity                                                            □
           Checking of near-field hydrophones (tap test)                                         □
           Checking of string depth ropes                                                        □
           Checking of string depth sensors                                                      □
           Checking of birds/acoustics communications during and after deployment                □
           Checking of bird depth sensors before deployment                                      □
           Checking of acoustic network and offsets                                              □
           Checking of data gain                                                                 □
           Checking of echosounder velocity                                                      □
           Checking of DGPS/rGPS systems                                                         □
           Performing a test line                                                                □
           Checking of external SegD data header after test line                                 □
           Performing bubble period tests for each individual gun                                □
           Checking of gun line integrity                                                        □