Page 132 - Advanced Design Examples of Seismic Retrofit of Structures
P. 132
124 Advanced Design Examples of Seismic Retrofit of Structures
TABLE 3.1 Determination of the Performance Objectives for
Buildings—cont’d
Performance Level
Retrofit
Building Type Functionality Target Earthquake-1 Earthquake-2
center of national
documents)
Infrastructure Main buildings of Special B-1 C-3
refinery, power
plants,
petrochemical
centers, chemical
factories
Important Universities, Enhanced C-3 E-5
schools, institutes
Provincial offices Enhanced B-2 E-5
of ministries and
central offices of
organizations
Public Municipality Enhanced C-3 E-5
saloons,
religious-related
buildings,
cinemas and
theatres,
stadiums,
libraries,
terminals, malls
and rooms with
capacity of more
than 300 persons
Residential, Basic C-3 –
office-
commercial
buildings, hotels,
parking
buildings,
industrial
buildings
Agricultural Basic or D-4 –
stores, aviculture limited
buildings and
temporary
buildings