Page 133 - Advanced Design Examples of Seismic Retrofit of Structures
P. 133

Example of an RC Building Retrofitted by RC Shear Walls Chapter  3 125



               TABLE 3.2 Results of the Qualitative Evaluations Phase

               Parameters affecting    l Serious changes in design codes since the 1960s
               vulnerability             and significant increase in the design-level
                                         earthquakes
                                       l Necessity of using ribbed bars in structural
                                         members and modifications in the reinforcing
                                         bars details
                                       l Selected structural system considering the plan
                                         dimensions and the number of stories
                                       l Improper arrangement of structural members
                                       l Arrangement of the RC shear walls in the plan of
                                         the building and torsional forces
                                       l Irregularities in plan and elevation
                                       l Large openings in diaphragms
                                       l Small distance between the two parts of the
                                         building and the possibility of pounding during
                                         earthquakes
                                       l It was found that the DCR under gravitational
                                         loads of a majority of the columns in the first story
                                         in the southern building part is 0.7. This ratio is
                                         even higher for the corresponding columns in the
                                         northern building part
               Causes of vulnerability of  l Low strength columns
               structural members      l Low strength RC shear walls
                                       l Reinforcing bars details
               Causes of vulnerability of  l Improper detailing of the large window
               non-structural members



                exceedance in 50 years or 475 years of returning period) and the Collapse
                Prevention (CP) performance level in Earthquake-2 (2% probability of
                exceedance in 50 years or 2475 years of returning period) should be provided.
             The summary of the evaluations in this phase is presented in Table 3.2.
                Based on the results above, the building is vulnerable to Earthquake-1 and
             Earthquake-2. A more accurate determination of the vulnerability of the build-
             ing is calculated after carrying out the field evaluation, material testing and
             quantitative study. Details of material testing based on Instruction for Seismic
             Rehabilitation of Existing Buildings (Code 360) [1] are presented in Table 3.3.



             3.2.1 Field Testing
             A complete set of standard testing of materials, structural details, soil condition,
             and groundwater level were performed and the results are presented
             briefly here.
   128   129   130   131   132   133   134   135   136   137   138