102                        Advanced gas turbine cycles

                                                        HRSG
                AIR                                                     EXHAUST




















                                                       SATURATOR

                             Fig. 6.15. Cascaded humid air turbine (CHAT) plant.

          move the compression towards isothermal rather than adiabatic, with the consequence of
          reduced work input. Now the claim is for an efficiency higher than that of the HAT cycle,
          and  this  may  be expected from  the  analysis  of  the  dry  ‘van Liere’  cycle  given  in
          Section 6.3.1.

                                   FUEL I
                    AIR

                       II

                           C
                       I





                                                              HEAT
                                                              EXCHANGER


                           -=F@+ WATER



                                                       CONDENSER             *

                     Fig. 6.16. TOPHAT (van Liere) plant with water injection into compressor.