Page 520 - Battery Reference Book
P. 520

Table 50.7  High-performance Piante-type lead-acid  standby power storage batteries available from Chloride Industrial Batteries
 Final   Cell type
 voltage
 (V)   YHP 11  YHP 13  YHP 15  YHP 17  YHP 19  YHP 21  YHP 23  YHP 25  YHP 27  YHP 29  YHP 31  YHP 33  YHP 35  YHP 37  YHP 39  YHP 41
 Capacity*
 at  15°C (Ah)
 when discharged in
 10h   1.85   500   600   700   800   900   1000   1100   1200   1300   1400   1500   1600   1700   1800   1900   2000
 3h   1.80   406   487   568   649   730   811   892   973   1054   1135   1217   1298   1379   1460   1541   1622
 Ih   1.75   300   360   420   480   540   600   660   720   780   840   900   960   1020   1080   1140   1200
 Capacity"
 at 25°C (Ah)
 when discharged in
 10h   1.85   536   643   750   858   965   1072   1179   1286   1394   1501   1608   1715   1822   1930   2037   2144
 3h   1.80   438   526   614   702   789   877   965   1052   1140   1228   1315   1403   1491   1578   1666   1754
 lh   1.75   327   392   458   523   589   654   719   785   850   915   981   1046   1112   1177   1242   1308
 Charge current (A)
 Starting   -   70   84   98   112   126   140   154   168   182   196   210   224   238   252   266   280
 Finishing   2.7   35   42   49   56   63   70   77   84   91   98   105   112   119   126   133   140
 Weight of  cell
 complete (kg)
 Filled   95.2   106.2   133.5   144.5   155.5   179.3   190.4   218.0   220.0   240.1   268.3   279.2   290.2   318.2   329.2   340.2
 Acid only, relative
 density  1.210   32.2   30.6   45.3   43.7   42.1   53.3   51.8   66.8   65.2   63.7   79.3   77.6   76.0   91.4   89.8   88.2
 Approx. quantity of                                            2
 acid, relative density                                         3
                                                                Q
 1.210 (litres)   27.1   25.7   38.1   36.7   35.4   44.8   43.5   56.1   54.8   53.5   66.6   65.2   63.9   76.8   75.5   74.1  3
                   __                     ___._                U
 * Larger capacitieh can he obtained by connecling cells in parallel. Smaller capacities are available in the YAP range (15-75  Ah) and YCP range (100-425  Ah)
                                                                4
   515   516   517   518   519   520   521   522   523   524   525