Plants and Equipment                                                                                343


               rotors plus the end of the idler rotor bearing against the  get the liquid up to pressure, but a necessary means of
               casing. Some manufacturers use an enlarged end on the  controlling the flow.
               rotors to increase bearing surface. Other schemes include     When  we’re dealing  with on-off  pump control
               balancing lines between suction and discharge ends ap-  there are opportunities to improve that method of con-
               plied to balance pressure forces. Another scheme is oppo-  trol to reduce energy costs and wear and tear on the
               site hand ends of the rotors so they draw liquid from both  pump. An attitude of limiting the number of starts by
               ends and discharge in the middle to balance the hydraulic  extending run time is one you should adopt. I’m not
               pressures almost completely.                         talking about recirculating liquid to keep the pump run-
                    Screw and gear pumps do not do a very good job  ning, that saves starts but also wastes energy. It is an
               of pumping compressible fluids. An oil pump can easily  option you should consider if the pump has extremely
               get air bound where there is a sufficient volume of air or  short off cycles where it may run for ten minutes then
               vapors at the discharge and inlet to expand and contract  shut down for five to ten seconds. If that’s the case then
               as each cavity between rotors is opened and closed, thus  recirculating some liquid to keep it running past those
               preventing  any  flow  through  the  pump.  The  air  also  short off cycles will save on pump and motor wear and
               leaks back just like the oil. It’s not uncommon for the  reduce wear and tear on the starter as well.
               pump to generate a loud audible roar when air or vapor     Every time the pump is started the entire assembly
               is trapped in it because the air or vapor doesn’t do a very  is subjected to stresses above and beyond the normal
               good job of lubricating the pump and it forms bubbles in  operating conditions. Motor current is five to ten times
               the oil as it leaks back.                            normal operating current when the pump is started and
                    Operating a screw or gear pump with a vapor trap  those high currents produce rapid heating of the motor
               for any extended period of time will ensure complete  windings with attendant thermal stresses and also high
               breakdown of the film of lubricating oil on the rotating  magnetic forces that can dislodge the windings. The run
               parts with subsequent damage to the pump as the metal  then stop and run then stop operation is also rough on
               parts start rubbing. It’s necessary to vent them to elimi-  bearings, both in the motor and in the pump, because
               nate compressing air or vapors in the pump that will  the bearings will heat up and cool down with some
               prevent liquid entering. Properly vented the pump will  breathing that can increase the probability of air mix-
               move air to eliminate it from the suction piping.    ing into the grease or oil to corrode them (see Chapter
                    When starting a dry pump (filled with air) it’s  6, Lubrication). The pump always experiences pressure
               important to ensure that lubricant film is maintained.  spikes when starting because the liquid in the connect-
               Making certain some of the piping is full of oil that will  ing piping has  to  be  accelerated  from  its  stationary
               be drawn into the pump is important to limit wear. The  position and the check valve has to be lifted. By reduc-
               oil is also a sealing film that helps the pump trap the air  ing starts you’ll reduce the strain on the equipment to
               in its cavities and push it through. The best way to do it  extend its life.
               is to fill the suction strainer with oil, shutting down at     Reduce starts by stretching the pump’s on-off set-
               regular intervals and repeating the process until all the  tings as far as you can. Let the level get a little lower and
               air or vapor is pumped out. Once you have a suction line  run the pump until it’s a little higher by adjusting the
               full of liquid the pump will work.                   level controller. There are limits to this, including allow-
                                                                    ing the level in a boiler to get so low that a little upset
               Pump Control                                         results in operation of the low water cutoff. All that re-
                    There was a time when the only control we had  ally does is tell you where the low limit is.
               over the operation of a pump was to turn it on or turn     I doubt if you can take advantage of that to get
               it off. That’s still a common means of controlling the  something replaced. I ran into one operator that was
               pumping of liquids, used almost exclusively for feed-  starting and stopping a pump repeatedly keeping his
               ing low pressure boilers and returning condensate but  hands on the enclosure with his two thumbs on the start
               modern technology has expanded our abilities and the  and stop buttons. When asked about it he responded
               wise operator should know how to utilize those meth-  “I’m trying to blow this damn thing up so they’ll give me
               ods. Note that this involves controlling the pump to  one that works.” On a repeat visit to the plant I noticed
               control the flow. Before variable speed pump control we  a new identical pump had replaced it. The operator was
               typically controlled the fluid flow to maintain operating  still grumbling because he got the same make and model
               parameters. Many times  that meant  recirculating  the  pump back so it still didn’t do what he wanted it to do.
               liquid that was pumped, wasting the energy we used to     As for controlling the flow through a pump auto-