Page 299 - Buried Pipe Design
P. 299

270   Chapter Five

          TABLE 5.10 Required Strength Based on SF   1.5 and Ultimate
          Bedding        Three-edge,  D load,
           class   LF       lb/ft     (lb/ft)/ft  Nonreinforced  Reinforced
            B      1.9      2046       1637     Choose class 1   Choose class III
                                                (2600)         (2000)
            C      1.5      2592       2074     Choose class 2   Choose class IV
                                                (2600)         (3000)
            D      1.1      4025       3220     Not available  Choose class V
                                                               (3750)


             Prestressed concrete pipe may be designed by the cubic parabola method,
           as discussed in Chap. 4. Equation (4.14) is as follows:

                                          3 P o   p
                                  W   W o                            (4.14)
                                             P o

           For lined cylinder:

                             p   0.8P o  (see AWWA C301)

           For embedded cylinder:

                                       (see AWWA C301)
                              p   P o

           From Example 5.3,
                                   W d   2112 lb/ft


           The required strength is
                                2112                         2
                          W d
                     W                 1111 lb/ft  p   150 lb/in
                          LF     1.9

           Therefore,
                              150            2
                          P o        187.5 lb/in for lined pipe
                               0.8

                   Total load W   W d   W L   2452  (see Example 5.3)


         Lined-cylinder pipe
         For lined-cylinder pipe,
   294   295   296   297   298   299   300   301   302   303   304