Page 44 - Buried Pipe Design
P. 44

22   Chapter Two

         undisturbed soil. The Marston tunnel load equation is

                                W t   C t B t ( B t   2C)             (2.9)

         where W is the load on the pipe in pounds per linear foot and   is spe-
                 t
         cific weight. The load coefficient C t is obtained in the same way that
         C was determined (see Fig. 2.2).  And  B is the maximum tunnel
                                                  t
           d
                                        is the OD of the pipe. The coefficient
         width; or if the pipe is jacked, B t
         C is called the cohesion coefficient and is, dimensionally, force per unit
         area (lb/ft ).
                   2
                                                       as well as  C . This
           Equation (2.3) can be used  in calculating  C t          d
         equation indicates that for very large values of H/B, C approaches a
                                                             t
         limiting value of 1/(2K ′). Thus, for very deep tunnels, the load can be
                                                            .
         closely estimated by using the value of 1/(2K ′) for C t
           It is readily apparent that the theory for loads on pipes in tunnels or
         being jacked through undisturbed soil is almost identical to the theory for
         loads on pipes in trenches. The tunnel load will be somewhat less because
         of the soil cohesion. It is also apparent from Eq. (2.9) that C is very impor-
         tant in determining the load. Unfortunately, values of the coefficient C
         have a wide range of variation even for similar soils. The value of C may
         be determined by laboratory tests on undisturbed samples. Conservative
         values of C should be used in design to account for possible saturation of
         the soil. It has been suggested that about one-third of the laboratory
         determined value should be used for design. The Water Pollution Control
         Federation (WPCF) Manual of Practice, No. FD-5, recommends the use
                                                      6
         of values given in Table 2.4 if reliable laboratory data are not available or
         if such tests are impractical. It is also suggested that this coefficient be
         taken as zero for any zone subjected to seasonal frost and cracking or loss
                                                      2C cannot be negative.
         of strength because of saturation. The factor  B t
         Therefore, 2C cannot be larger than  B .
                                            t
         Flexible pipe
         A flexible pipe derives its soil-load-carrying capacity from its flexibility.
         Under soil load, the pipe tends to deflect, thereby developing passive

         TABLE 2.4 Recommended Safe Values of Cohesion C
                                   Values of C
                  Material       kPa     lb/ft 2
               Clay, very soft    2        40
               Clay, medium      12       250
               Clay, hard        50      1000
               Sand, loose, dry   0         0
               Sand, silty        5       100
               Sand, dense       15       300
   39   40   41   42   43   44   45   46   47   48   49