Glass Pr ocesses for Other Applications 169
Internal transmission for 100 cm of C1 fiber
PERKIN ELMER
5000 4000 3500 3000 2500 2000 1500 1000 cm –4
100.00
%T + 0.4
80 7.8902; 85.91%T 1
% Transmission 60 2.0012; 80.13%T 2.3217; 77.56%T 3.5488; 73.21%T 4.1122; 75.11%T 9.2237; 78.54%T 3 ABS (dB/m)
40
4.6017; 5.45%T 5
20 10.5927; 30.71%T 11.9580; 5.80%T 10
0.00
2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000
94/12/09 14:24 Wavelength (µm)
X: 25 scans, 4.0 cm –1
1.5 vs .5 m Bgr. C1 Fiber, 94-131-5, ∗9.27 C02 value
FIGURE 7.11 AMI FTIR transmission scan of C1 fi ber of 1 m length.
Internal transmission for 100 cm of C2 fiber
PERKIN ELMER
6500 5500 5000 4500 4000 3500 3000 2500 2000 1500 cm –4
100.00
%T CO laser trans. a 5.25, 0.2 dB/m
80 1.5895; 90.81%T 2.1976; 91.37%T 5.2506; 91.24%T 1
% Transmission 60 6.3216; 70.38%T 3 ABS (dB/m)
40
2.9039; 34.05%T 10
20 4.0378; 0.48%T 6.8831; 12.95%T 7.5953; 2.09%T 5
0.00
1.500 2.000 2.500 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500
Wavelength (µm)
95/03/14 17:51
Z: 25 scans, 4.0 cm –1
As 2S3, C2, Fiber, 30 mil Clad, 1.5 m vs .5 m