Page 260 - Chemical Process Equipment - Selection and Design
P. 260

TABLE 8.24. Comparative Data of Freon Refrigerants

 Refrigerant Number (AM Designation)   11   12   22   113   114   500        502

                                                                         azeotrope of
                                                      azeotrope of       monochlorodi-
                                                       dichlorodi-      fluoromethane
                                                     fluoromethane           and
 trichloromono-   dichlorodi-   monochlorodi-   trichlorotri-   dichlorotetra-   and   monochloropenta-
 Chemical name   fluoromethane   fluoromethane   fluoromethane   fluoroethane   fluoroethane   difluoroethane   fluoroethane
                                                      73.8% CCI,F,       48.8% CHCLF,
 Chemical formula   CCI,F   CCI,F,   CHCIF,   CCI,F-CCIF,   C,W4   26.2% CH,CHF,   51.2%  CCIF,-CF3
 Molecular wl   137.38   120.93   86.48   187.39   170.93   99.29           111.64
 Gas constant R [(ft Ib/lb R)]   11.25   12.78   17.87   8.25   9.04   15.57   13.87
 Boiling point at 1 atm (“F)   74.7   -21.62   -41.4   117.6   38.4   -28.0   -50.1
 Freezing point at 1 atm (“F)   -168   -252   -256   -31   -137   -254        a
 Critical temperature (“F)   388.0   233.6   204.8   41 7.4   294.3   221.1   194.1
 Critical pressure (psia)   635.0   597.0   716.0   495.0   474.0   631  .O   618.7
 Specific heat of liquid, 86°F   0.220   0.235   0.335   0.218   0.238   0.300   0.305
 Specific heat of vapor,  C,  60°F at 1 atm   a   0.146   0.149   a   0.156   0.171   0.164
 Specific heat at vapor,  C,  60°F at 1 atm   a   0.130   0.127   a   0.145   0.151   0.161
 Ratio CJC,  = K (86°F at 1 atm)   1.11   1.14   1.18   1.12   1.09   1.13    1.023
 Saturation pressure (psia) at
 -50°F   0.52   7.12   11.74   a         1.35              8.395             14.74
 0°F   2.55   23.85   38.79   0.84       5.96             27.96              45.94
 40°F   7.03   51.67   83.72   2.66     15.22             60.94              94.90
 105°F   25.7   141.25   227.65   11.58   50.29          167.85             244.40
 Net  refrigerating  effect  (Btu/lb) 40-105°F  (no   67.56   49.13   66.44   54.54   43.46   59.82   43.72
 subcooling)

 Cycle efficiency (% Carnot cycle) 40-105°F   90.5   83.2   81.8   87.5   84.9   82.0   76.1
 Liquid circulated 40-1 05°F [(lb/min/ton)]   2.96   4.07   3.02   3.66   4.62   3.35   4.58
 Theoretical displacement 40-105°F   16.1   3.14   1.98   39.5   9.16   2.69   2.04
 (cuft/min/ton)J
 Theoretical horsepower per ton 40-105°F   0.676   0.736   0.75   0.70   0.722   0.747   0.806

 Coefficient  at  performance 40-105°F  (4.71/HP   6.95   6.39   6.29   6.74   6.52   6.31   5.86
 per ton)
 Cost compared with R  11   1  .oo   1.57   2.77   2.15   2.97   2.00         5.54

 a Data not available or not applicable.