Page 355 - Chemical process engineering design and economics
P. 355

334                                                      Chapter 6

           Table 6.27 Continued

           Feed Plate Location
                                       2
           Nu / N L = [ (X HK/X LK) F (x LK,B/x HK,D)  (B / D) f 206  (6.27.12)
           N e = Nu + N L                                            (6.27.13)
           Column Height
           Tray Columns


           N A = N e /E 0                                            (6.27.14)
           Z = N A x Tray Spacing + L s + 4.0 ft                      (6.27.15)
           Tray Spacing  —  from Table 6.25

           L s = 4 V B t s'  / 7i (D') 2  —  D is calculated using Tables 6.23 and 6.24  (6.27.16)

           Packed Columns

           Z = N e x (HETS) + L s + 4.0 ft                           (6.27.17)
           Column Diameter

           Follow the procedure outlined in Table 6.23
           System Properties

           OC^KJ/KHK                                                 (6.27.18)
           (ai)avg = (oCi F a iD a iB ) 1/3                          (6.27.19)

                              i
           a F  = I; Xj  F' a;  F  —  a  F calculated at (T T + T B)/2  (6.27.20)
                   OC F)  —  Figure 6.17                             (6.27.21)
           E 0 = f(u F
           Ki =  yi/Xi                                               (6.27.22)

           K ; = f(T',P')                                            (6.27.23)

                I
            u-F = i X i F ' H i F                                    (6.27.24)
            u iF = f[(T T + T B)/2]                                  (6.27.25)

           HETS = D'  —  for D < 0.5m                                (6.27.26)
                         3
           or HETS = (D')°  —  for D > 0.5m



         Copyright © 2003 by Taylor & Francis Group LLC
   350   351   352   353   354   355   356   357   358   359   360