Page 158 - Corrosion Engineering Principles and Practice
P. 158

132   C h a p t e r   5     C o r r o s i o n   K i n e t i c s   a n d   A p p l i c a t i o n s   o f   E l e c t r o c h e m i s t r y    133


                                  Sensor Elements
                                                                        Insulator


                          e –      e –                 e –   e –
                                     e –  e –
                                                          e –
                                             e –

                             e –                     –  e –
                                e –          e –  e –  e

                                                                      Resistor




                          Coupling Joint              Multiplexing Data Logger
                                                Measuring Current Through Each Resistor
                      FIGURE 5.38  Multielectrode array multiplexed current and/or potential
                      measurement (adapted from [26]).
                          •  H S systems
                              2
                          •  Oil/water mixtures
                          •  Cathodically protected systems
                          •  Cooling water
                          •  Simulated crevices in seawater

























                      FIGURE 5.39  Typical CMAS probes used for real-time corrosion monitoring.
                      (Courtesy of Corr Instruments, LLC)
   153   154   155   156   157   158   159   160   161   162   163