               TABLE 13.9 Function of pertinence of the severity according to the oil.
               Zone          Qualification  Operation of machines
               A             [N] Normal   Commissioned machines should generally
                                          operate in this area
               Water% volume  % # 0.2
               Micron iron   % # 49
               content
               Micron copper  % # 19
               content
               B             [A] Alert    Unsatisfactory for continuous operations for
                                          long periods
               Water% volume  0.3
               Micron iron   50
               content
               Micron copper  20
               content
               C             [C] Critical  It is sufficient to cause damage to the machine
                                          at any time
               Water% volume  Above 0.3
               Micron iron   Above 51
               content
               Micron copper  Above 21
               content











               TABLE 13.10 thermography to determine hot spots.
               (Zone)                 (Thermography)
               (A)                    ([N] Normal less or equal 94.0 F)
               B                                   [P] Permissible
               (B/C)                  (94.0 F)                (164.2 F)
               C                                     [A] Alert
               (C/D)                  (164.2 F)               (199.3 F)
               (D)                    [C] Critical above 199.3 F