Page 266 - Estimators Piping Man Hour Manual
P. 266

Section Eleven—TECHNICAL INFORMATION          241



























                                       Figure 1
                            NOTE;  Maximum  Allowable  Load  at B  =  650tb




                                   Table  of  Weights

                              Weight   Insulation  Total  Weight  Used in  .,  .
             Description
                             in  Pounds  Weight in  Pounds  Weight  Calculations
       12*-Schedule  160 Pipe  161       36.5     197.5      197  5    Per Ft
        6*-Schedule  160 Pipe  45.3      24  2     69.6      69.5      Per Ft,
       12*-900Jb Stop and  Check Valve  3960  394.0  4354  0  4354.0   Each
       12*-900tt>  Lap Flange  445       54.75    499  75    500.0     Each
       12"  X  12" X fi"-<K)Olti Flanged Tee  1683  321  0  2004  0  2004.0  Each
       12*-900ft»  Flanged  (lute Valve  4024  394.0  441H  0  4418.0  Each
       12"-Sehedulp  IfiO  Weld  K1I  460  109  5  569  5    570  0    Each
        6*-W.N.F.S.  900ttv  Flange  116  36.3    152  3     1520      Each
        6*-Sch«lulft  160  \V<-1<1  ICI1  59  3fi  3  95  3  95.0      Each
        6*-90011j Flanged  Globe Valve  1100  217.8  1317  S  13180    Each
       12"-900!b Flanged  Elbow  1598   226.3     1824.3    18240      Each