Page 158 - Failure Analysis Case Studies II
P. 158

143




























                      Fig.  6. Optical micrograph of the  En32 steel immediately  adjacent to the weld showing  cracks that  originated after the
                      nitriding (etchant: 2% Nital).




























                      Fig. 7. SEM fractograph of the fracture surface as received. The intergranular nature of the fracture and secondary cracks
                      can be seen.

                                                    4. DISCUSSION

                       The absence of evidence of fatigue and the short operational life of the actuators indicated that
                      the components entered service flawed or contained  such high residual stresses in the weld  that
                      operational loading resulted in cracking and fracture.
                       Table 2 shows the nickel and chromium equivalents of the various steels used. The exact extent
                      of dilution of the weld metal was not determined, but the combination of the parent metals and
                      E3 12 filler metal places the resultant weld metal composition into the A + F or A + M + F zone on
                      the Schaeffler diagram.  Since the welds were very wide and a large degree of dilution  had taken
   153   154   155   156   157   158   159   160   161   162   163