FLOW MEASUREMENT    87































                                                  Double U-tube Coriolis mass flow meter designs.
                                      FIGURE 4.30

                & Bent tube Coriolis flow meters are preferred wher-    the readings. They must be properly sized for the flow
                  ever highly accurate, reliable, rangeable mass flow is  rates involved.
                  required.                                          & Temperature is constantly measured because the
                & Straight tube meters are preferred when raw material  oscillatory properties of the tube vary with
                  contamination is to be avoided. Between runs of the  temperature.
                  same material or between runs of different materials  & Use of these meters is limited for smaller pipe sizes
                  it may be necessary to avoid cross-contamination     (usually 7–10 cm) as they become expensive for
              . What are the applications of Coriolis flow meters?      larger pipe sizes.
                & Used for clean liquids and gases flowing fast enough  & Some low-pressure gases do not have sufficient
                  to operate the meter.                                density to operate the meter.
                & Coriolis meters can be used to measure flow of both  & The main limitation of the Coriolis meter is that
                  liquids and gases.                                   pressure drop can become large as fluid viscosity
                & These meters can be used to measure the flow of some  increases.
                  fluids with varying densities that cannot be measured  & Coriolis flow meters have a relatively high initial
                  by other flow meters.                                 cost, which is offset by normally low maintenance
              . What are the limitations of Coriolis flow meters?       costs.
                & These meters are sensitive to pipe and building  . What type of application Coriolis flow meters is par-
                  vibrations.                                       ticularly advantageous over conventional ones?
                & Not suitable for flow measurement involving slug    & General-purpose gas or liquid flow.
                  flow of two-phase gas–liquid systems. Entrained air  & Blending ingredients and additives.
                  or gases in liquid flow measurement could cause     & Conducting a primary check on secondary flow
                  significant errors in measurements. They under pre-   meters.
                  dict the actual flow rates at low void fractions    & Metering natural gas consumption.
                  and over predict flows at high void fractions of
                                                                     & Monitoring such fluids as syrups, oils, suspensions,
                  entrained gases. Such errors could be as high as
                                                                       and pharmaceuticals.
                  20% or more when entrained gases or low flow rates
                                                                     & True mass flow capability of Coriolis meters provide
                  are involved.
                                                                       accurate flow requirement of expensiveraw materials
                & Over sized meters could result in low flow rates
                                                                       without wastage, for example, detergents, shampoos,
                  which reduce Coriolis effect and hence accuracy of
                                                                       and toothpastes.