Page 111 - Fluid mechanics, heat transfer, and mass transfer
P. 111

FLOW MEASUREMENT
            88
                 & Well suited for cryogenic applications involving    temperature should be maintained at a factor
                  LNG, liquid helium, and so on.                       of at least three times the value of DP across the
                 & With normal flow measuring devices, equipment and    meter.
                  components are affected by extreme cold conditions.  & A logical way to minimize flashing is to limit DP by
                  Moving mechanical parts, wetted seals, and other     specifying a meter that is larger than that might
                  parts can cease to function, fail prematurely or give  be used in comparable noncryogenic service.
                  rise to other problems.                              Advanced digital signal processing makes it possible
                 & A complication arises because the cost of keeping   to filter out the noise associated with a large meter at a
                  cryogenic fluids cold enough to remain in the liquid  high turndown and still achieves a highly accurate
                  state goes up as the temperature goes down. Common   result.
                  practice is to keep cryogenic fluids at temperatures
                  only slightly below their boiling temperatures. As a  4.1.7  Positive Displacement Flow Meters
                  consequence, as the fluid flows through a pipeline or
                  past an obstacle like valve, DP, even small, can cause  . What are positive displacement flow meters?
                  flashing to take place. Small or large pockets of gas  & Operation of positive displacement meters consists
                  form in the liquid, which makes flow measurement      of separating liquids into accurately measured incre-
                  erroneous.                                           ments and moving them on. Each segment is counted
               . Summarize the plus and minus points of Coriolis flow   by a connecting register. Because every increment
                meters.                                                represents a discrete volume, positive-displacement
                                                                       units are popular for automatic batching and account-
                 & Plus points:
                                                                       ing applications. Positive displacement meters are
                  ➢ Higher accuracy than most flow meters ( 0.1%
                                                                       good for measuring the flows of viscous liquids or for
                    for mass flow).
                                                                       use where a simple mechanical meter system is
                  ➢ Can be used in a wide range of liquid flow
                                                                       needed.
                    conditions.
                                                                   . What are the characteristic features and applications of
                  ➢ Measures the mass flow rate directly, which elim-
                                                                     positive displacement flow meters?
                    inates the need to compensate for changing tem-
                                                                     & Positive displacement meters provide high accuracy
                    perature, viscosity and pressure conditions.
                                                                       ( 0.1% of actual flow rate in some cases) and good
                  ➢ Ideally suited to products that are accounted for on
                                                                       repeatability (as high as 0.05% of reading). Accuracy
                    a mass basis, such as LPG, NGL, ethylene, and
                                                                       is not affected by pulsating flow unless it entrains air
                    CO 2 .
                                                                       or gas in the fluid.
                  ➢ Capable of measuring hot (e.g., molten sulfur and  & PD meters do not require a power supply for their
                    liquid toffee) and cold (e.g., cryogenic helium and
                                                                       operation and do not require straight upstream and
                    liquid nitrogen) fluid flow.
                                                                       downstream pipe runs for their installation.
                  ➢ Low maintenance, because there are no parts that
                                                                     & PD meters are available in sizes from 6 to 300 mm
                    wear with time.
                                                                       (one-fourth in to 12 in.) and can operate with turn-
                  ➢ The meters can be significantly over ranged with-   down ratios as high as 100:1 although ranges of 15:1
                    out causing damage to the sensor.                  or lower are common.
                  ➢ Low DP.                                          & PD meters operate with small clearances between
                  ➢ Suitable for bidirectional flow.                    their precision-machined parts.
                 & Minus points:                                     & As fluid viscosity increases, slippage between the
                  ➢ High initial setup cost.                           flow meter components is reduced, and metering
                                                                       accuracy is therefore increased. Although slippage
                  ➢ Clogging may occur and difficult to clean.
                                                                       through the meter decreases with increased fluid
                  ➢ Larger in overall size compared to other flow
                                                                       viscosity (i.e., accuracy increases), pressure drop
                    meters.
                                                                       through the meter also increases.
                  ➢ Limited line size availability.
                                                                     & The maximum (and minimum) flow capacity of the
               . How does flashing is avoided or minimized in cryogenic
                                                                       flow meter is decreased as viscosity increases. The
                applications of Coriolis flow meters?
                                                                       higher the viscosity is, the lesser the slippage and the
                 & A good rule of thumb for avoiding or minimizing     lower the measurable flow rate are.
                  flashing is that the difference between the discharge  & As viscosity decreases, the low flow performance of
                  pressure and the liquid vapor pressure at the fluid   the meter deteriorates.