Page 73 - Forensic Structural Engineering Handbook
P. 73

TABLE 1.4 Council of American Structural Engineers Submittal Review Checklist (Continued)


           Project:         Project Manager:        Reviewer:
           Project No.:     Engineer:               Date:



                         Item               Yes   No  N/A       Comment

             B. Are element depths and sizes
                correct?
             C. Is fire rating correct?
             D. Is general layout correct?
             E. Are connections to primary struc-
                tural frame appropriate?
             F. Do plank details allow for neces-
                sary diaphragm action?
             G. Do details allow for adequate load
                transfer to supporting elements?
             H. Are drawings certified by a regis-
                tered P.E. in project’s jurisdiction?
             I.  Have certified calculations been
                reviewed?
             J.  Have unusual loadings been
                included (partitions and equipment
                pads)?
             K. Are steel coatings (epoxy and gal-
                vanizing) correct?
             L. Are embeds in correct locations?
             M. Have opening and notch sizes and
                locations been verified with archi-
                tectural, mechanical, and electrical
                drawings?
            VI. Structural Steel
             A. Have certified calculations and con-
                nection drawings been submitted if
                required by contract documents?
             B. Are steel grades correct for each
                element?
             C. Are shear stud sizes, type, length,
                quantity, and layout correct?
             D. Are baseplate elevations, column
                top elevations, and top of beam
                elevations correct?
             E. Is camber correct for each beam?



                                          1.54