TABLE 1.4 Council of American Structural Engineers Submittal Review Checklist (Continued)


           Project:         Project Manager:        Reviewer:
           Project No.:     Engineer:               Date:



                         Item               Yes   No  N/A       Comment

             B. Have critical lengths been
                spot-checked?
             C. Are bridging types, sizes, and
                spacing correct?
             D. Are details consistent with
                structural drawings?
             E. Are ceiling extensions provided, if
                required?
             F. Are bearing depths and elevations
                consistent with structural drawings?
             G. Are weld sizes and lengths at
                bearing details adequate?
             H. Are sizes consistent with any fire
                assembly rating requirements?
             I.  Is surface preparation correct?
             J.  If calculations have been provided,
                are they consistent with shop
                drawings?
             K. Are cambers in accordance with
                structural drawings?
             L. If required by contract documents,
                are joists supplied by a member of
                SJI?
             M. If “special design” joists are
                supplied, are fabricator’s design
                loadings consistent with structural
                drawings?
             N. If concentrated loads are supported
                off joists, are they located at panel
                points?
             O. If concentrated loads are not located
                at panel points, are adequate
                diagonal elements provided?
            VII. Steel Deck
             A. Are deck gages correct?
             B. Are depths, span direction, and type
                correct?