Be st Practice 7 .26          Lube, Seal and Control Oil System Best Practices

        Item   Description        Specified Actual Witnessed  Item  Description         Specified Actual Witnessed
                                  value   value  by                                    value   value  by
        7.     Record the following:                               PDAL actuates read on
        7A.    Pump disch. press on PI  Approx.  _____             PDI
                                  2600                       14.   Bleed pressure off PSL  76 kPa
        7B.    Oil temp. upstream on TI  Less than _____           (low oil trip switch) and  Falling  ______
                                  65 C                             observe:


        7C.    Oil temp. downstream on 49 C                        A. Annun. PALL functions
               TI                                                  Read PI
        7D.    Cooler/filter DP on PDI  Less than                   B. T&T valve closes
               Switch transfer valve and  70 kPa  _____            C. Valve rack closes
               record:                                       15. (see Increase temporary N 2
               Bank ‘A’ DP                _____              Note 2) press on PDSLL (L.P.
               Bank ‘B’ DP                                         case seal low DP trip
        7E.    Lube press at console on  ) Approx.  _____          switch) and observe that:
               PI                 283 kPa                          A. Annun. PDALL     138 kPa  ______
                                  )
        7F.    Control press at console  1091  _____               functions.          Falling
               on PI              kPa                              Read on PDI
        7G.    LP case on DP PDI  241 kPad _____                   B. Action occurs as in 14
        7H.    HP case on DP PDI  241 kPad _____                   above
        7I.    Lube press at unit on PI  124 to  _____       16.   Repeat above for    138 kPa  ______
                                  138 kPa                          PDSLL(HP case seal low  Falling
        7J.    Control press at unit PI  883 kPa  _____            DP trip) and observe
        7K.    All ‘sight’ glasses show oil  _____                 Annun. PDALL functions
               flow                                                 at specified value. Read
        7L.    Lube oil head tank is full  e  _____                PDI
                                  )                          17.   Shut off aux. oil pump and  ______
        7M.    Turbine accumulator  Approx.  _____
               press on PI        900 kPa                          confirm all valves are
               ) Adjust as required to                             stable
               attain                                        18.   Time rundown of oil tank. Approx.
                                                                                       4"
               proper values at the unit
        8.     Record seal oil drainer                             Observe level switch LSL above
               level for each drainer for                                              Tang.
               one hour.                                           actuates Annun. LAL  Line   ______
                                                             19.   A. Disconnect main lube
               Drainer A          2 fills per  _____
                                                                   oil pump from turbine
                                  hour
                                                                   B. Drain steam inlet line to
               Drainer B                  _____
                                                                   main lube pump turbine
               Drainer C                  _____
                                                                   C. Drain turbine
               Drainer D                  _____
                                                                   D. Confirm turbine bearing
        9.     Switch transfer valve from
                                                                   cooling water is on
               ‘A’ to ‘B’ bank and
               observe                                             E. Confirm trip is reset
               press fluctuation on PI                        20.   Open inlet valve, gradually  ______
               and confirm that PSL                                 bring turbine up to speed
               does not actuate.                                   and confirm the following:
                                                                   A. Rated speed (Strobe  3600
        10.    Bleed low side of filter  241 kPa  _____
                                                                   Tac)                RPM
               switch PD SH and confirm Rising
                                                                   B. Inlet press PI   2274 kPa  ______
               PDAH
                                                                   C. Inlet temp. TI Temp  327 C  ______

               actuates at specified
                                                                   D. Exhaust press PI Temp 517 kPa  _____
               value.
                                                                   E. Vibration (using metrix  0.2 in/
        11.    Bleed pressure off PSL  90 kPa
                                                                   vibration instrument)  sec.
               (low oil press) and confirm Falling
               @ unit annun. PAL                             21.   Disable governor and  4140  _____
               actuatesatspecifiedvalue.                            check overspeed trip 3  RPM
                                                                   times.
               Read PI
        12.    Increase temporary N 2  207 kPa  _____        22.   Manually trip turbine using
                                                                   hand trip.
               press on PDSL (L.P. case Falling
               seal low DP alarm switch)                     23.   Check pump/turbine
                                                                   alignment and couple up
               and confirm
                                                                   main pump.
               Annun. PDAL actuates at
                                                             24.   Slowly bring pump up to
               specified value. Read PDI
        13.    Repeat above for PDSL  207 kPa  _____               speed and check:
                                                                   24A. Pump vibration  0.2 in/sec _____
        (see   (H.P. case seal low DP  Falling                     24B. Cavitation     None    _____
        note 2) alarm) confirm Annun.

                                                                   24C. Pump brg. temp.  165 F  _____