Page 313 - Geothermal Energy Systems Exploration, Development, and Utilization
P. 313
5.10 Stralsund (Germany) 289
0
Measured
100
Modelled
200
Draw down (m) 300
400
500
600
0 100 200 300 400
Time since start of test (days)
Figure 5.32 Hydromechanical coupled model used to fit
measured data. (McDermott et al., 2006.)
Stralsund
Stralsund
Germany
Gt Ss 1/85
Gt Ss 2/85
Gt Ss 6/89
N
0 5 10 15
Kilometeres
Geothermal bores Geological fault
Model area Urban area
Figure 5.33 Stralsund geothermal site with wells Gt
Ss 1/85, Gt Ss 2/85, and Gt Ss 6/89 (black dots). The
reservoir is partly delineated by impervious faults (black
lines). The model area (dotted rectangle) measures about
12 km × 6km.