Page 313 - Geothermal Energy Systems Exploration, Development, and Utilization
P. 313

5.10 Stralsund (Germany)  289

                              0
                                                       Measured
                            100
                                                       Modelled

                            200
                           Draw down (m)  300



                            400


                            500

                            600

                                0      100     200      300     400
                                       Time since start of test (days)

                         Figure 5.32  Hydromechanical coupled model used to fit
                         measured data. (McDermott et al., 2006.)


                                                                    Stralsund
                                                  Stralsund
                                                                Germany

                                       Gt Ss 1/85
                                      Gt Ss 2/85
                                         Gt Ss 6/89

                                                                     N





                          0        5        10       15
                                                        Kilometeres
                                   Geothermal bores     Geological fault
                                   Model area           Urban area

                         Figure 5.33  Stralsund geothermal site with wells Gt
                         Ss 1/85, Gt Ss 2/85, and Gt Ss 6/89 (black dots). The
                         reservoir is partly delineated by impervious faults (black
                         lines). The model area (dotted rectangle) measures about
                         12 km × 6km.
   308   309   310   311   312   313   314   315   316   317   318