(W/HZ), where W = flow rate, lb/h/1000; H = channel width, in; Z = fluid
               viscosity,  cp.  Substituting,  we  have,  for  the  hot  side,  N   =  (10,000)
                                                                                           Re
               (6225/1000)/(24)(3.35)  =  774.4.  For  the  cold  side,  N   =  (10,000)
                                                                                          Re
               (5925/1000)/(24)(8) = 308.6. Because both fluids are in laminar flow, spiral
               flow will be chosen for this heat exchanger. From Table 9, the appropriate

               expressions for rating are Eq. (3) for both fluids, Eq. (10) for the plate, Eq.
               (12) for fouling, and Eq. (15) for pressure drop.


                          TABLE 9 Empirical Heat-Transfer and Pressure-Drop Relationships
                     for Rating Spiral-Plate Heat Exchangers