Design of Connections for Axial, Moment, and Shear Forces

                           Design of Connections for Axial, Moment, and Shear Forces  123

                         Tearout between bolts will not control in this case since 3   0.9375
                         2.0625 > 1.281 or 1.031.
                         From the above, the shear/bearing/tearout strength of the flange
                         connection is

                                 R     2   27.1   2   2   26.9   2   2   27.1   2
                                  vpt
                                       324 kips > 311 kips, ok

                         In the expression for  R , the first term is for the two bolts in the
                                               vpt
                         center, which are controlled by shear; the second term is for the outer
                         two bolts controlled by outer plate edge distance; and the third term
                         is for the two inner bolts again controlled by bolt shear.
                           This completes the calculation for the flange portion of the splice.
                         The bolts, outer plate, and inner plates, as chosen above, are ok.

                    B. Web connection:
                       The calculations for the web connection involve the same limit states
                       as the flange connection, except for chord net section, which involves
                       flanges and web.
                       1. Member limit states:
                         a. Bolts: A bolt pattern is required to check the web.
                                                         178
                                    Number required            5 3.28
                                                       2 3 27.1
                           Try four bolts.
                         b. Bearing/tearout: This will be checked after the web splice plates
                           are designed.
                         c. Block shear fracture: Assume the bolts have a 3-in pitch
                           longitudinally.

                                A     (4.75   1.5   1)   0.440   2   2.86 in 2
                                  nv
                                A     (3   1   1)   0.440   0.88
                                  nt
                                A     4.75   0.440   2  4.18 in 2
                                  gv
                                 A   3   0.440   1.32 in 2
                                  gt
                              F A     65   0.88   57.2 kips
                                u  nt
                           0.6F A     0.6   65   2.86   112 kips
                               u  nv
                            0.6F A    0.6   50   4.18   125 kips
                                y  gy
                                U     1.0
                                  bs
                                R     0.75[57.2   min{115,125}]   127 kips   178 kips, no
                                  bs
                                      good



                 Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)
                             Copyright © 2009 The McGraw-Hill Companies. All rights reserved.
                              Any use is subject to the Terms of Use as given at the website.
   133   134   135   136   137   138   139   140   141   142   143