Since the block shear limit state fails, the bolts can be spaced out
to increase the capacity. Increase the bolt pitch from the 3 in
assumed above to 6 in. Then
A (7.75 1.5 1) 0.440 2 5.50 in 2
nv
A 0.88 in 2
nt
A 7.75 0.440 2 6.82 in 2
gv
A 1.32 in 2
gt
U 1.0
bs
F A 65 0.88 57.2 kips
u nt
0.6F A 0.6 65 5.50 214 kips
u nv
0.6F A 0.6 50 6.82 205 kips
y gv
R 0.75[57.2 min{214, 205}] 197 kips > 178 kips, ok
bs
The web bolt pattern shown in Fig. 2.32 is the final design. At this
point, there are four bolts in the web at 6-in pitch, but the six bolts
shown will be required.
1
2. Web plates: Try two plates, one each side of web, 6 in wide and /
2
in thick.
a. Gross area:
R 0.9 36 0.5 6 2 194 kips > 178 kips, ok
gt
b. Net area:
A (6 2 1) 0.5 2 4.0 in 2
nt
.85A 0.85 0.5 6 2 5.1 in 2
gt
R 0.75 58 4.0 174 kips 178 kips, no good
nt
5
Increase web plates to / in thick. Net area will be ok by inspection.
8
c. Block shear rupture: This is checked as shown in previous cal-
culations. It is not critical here.
3. Bearing/tearout: The bolt pattern and plates are now known, so
this combined limit state can be checked.
a. Bolt shear:
r 54.2 kips (double shear)
v
r 27.1 kips (single shear)
v
b. Bearing on W14 99 web:
r 0.75 2.4 0.875 0.440 65 45.0 kips
p
Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)