Page 139 - Handbook of Structural Steel Connection Design and Details
P. 139

Design of Connections for Axial, Moment, and Shear Forces

                    124    Chapter Two

                         Since the block shear limit state fails, the bolts can be spaced out
                         to increase the capacity. Increase the bolt pitch from the 3 in
                         assumed above to 6 in. Then

                                 A    (7.75   1.5   1)   0.440   2   5.50 in 2
                                  nv
                                 A   0.88 in 2
                                   nt
                                 A   7.75   0.440   2   6.82 in 2
                                  gv
                                 A   1.32 in 2
                                   gt
                                 U   1.0
                                   bs
                               F A   65   0.88   57.2 kips
                                u  nt
                            0.6F A    0.6   65   5.50   214 kips
                                u  nv
                            0.6F A   0.6   50   6.82   205 kips
                                y  gv
                                 R   0.75[57.2   min{214, 205}]   197 kips > 178 kips, ok
                                   bs
                         The web bolt pattern shown in Fig. 2.32 is the final design. At this
                         point, there are four bolts in the web at 6-in pitch, but the six bolts
                         shown will be required.
                                                                                   1
                       2. Web plates: Try two plates, one each side of web, 6 in wide and  /
                                                                                    2
                         in thick.
                         a. Gross area:
                            R   0.9   36   0.5   6   2   194 kips > 178 kips, ok
                              gt
                         b. Net area:
                                 A   (6   2   1)   0.5   2   4.0 in 2
                                  nt
                              .85A   0.85   0.5   6   2   5.1 in 2
                                   gt
                                 R   0.75   58   4.0   174 kips   178 kips, no good
                                  nt
                                             5
                         Increase web plates to  / in thick. Net area will be ok by inspection.
                                              8
                         c. Block shear rupture: This is checked as shown in previous cal-
                         culations. It is not critical here.
                       3. Bearing/tearout: The bolt pattern and plates are now known, so
                         this combined limit state can be checked.
                         a. Bolt shear:
                                        r   54.2 kips (double shear)
                                         v
                                        r   27.1 kips (single shear)
                                         v
                         b. Bearing on W14   99 web:
                              r   0.75   2.4   0.875   0.440   65   45.0 kips
                                p



                 Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)
                             Copyright © 2009 The McGraw-Hill Companies. All rights reserved.
                              Any use is subject to the Terms of Use as given at the website.
   134   135   136   137   138   139   140   141   142   143   144