Page 145 - Handbook of Structural Steel Connection Design and Details
P. 145

Design of Connections for Axial, Moment, and Shear Forces

                    130    Chapter Two

                                       1
                                             1
                                 1
                    welds for the  /   6 /   12 / strong axis stiffener are designed as fol-
                                  2     2      2
                    lows. For the weld to the inside of the flange, the force to be developed
                                                                           3
                    by the weld to the connected portion is 29 kips. Thus, the 5 / contact,
                                                                            4
                    which is the connected portion, is designed for 29 kips. The weld to the
                    flange is thus
                                                   29
                                    D 5                        5 1.21
                                     f
                                         2 3 5.75 3 1.392 3 1.5
                      An AISC minimum fillet weld is indicated. The factor 1.5 in the
                    denominator above comes from the AISC Specification, Section J2.4,
                    for transversely loaded fillets. The weld to the web has a length 12.5
                    0.75   0.75   11.0, and is designed to transfer the unbalanced force in
                    the stiffener to the web. The unbalanced force in the stiffener is 29 kips
                    in this case. Since the weld at the web and the weld at the flange do not
                    share load in this case, both the longitudinally and transversely loaded
                    welds can develop their full strength. Thus,

                                                   29
                                      D 5                    5 0.95
                                        w
                                            2 3 11.0 3 1.392
                    An AISC minimum fillet is indicated.

                    2.3.2.1 Doublers. The beam flange force (required strength) delivered
                    to the column is F   229 kips. The design shear strength of the column
                                    f
                     V   0.9   0.6   50   0.485   14.16   185 kips   229 kips, so a doubler
                       v
                    appears to be required. However, if the moment that is causing doublers
                    is  M   389 kips-ft, then from Fig. 2.34, the column story shear is
                         b
                                                      M b
                                                   5
                                                V s
                                                      H
                    where H is the story height. If H   13 ft,

                                                 389
                                            V s 5    5 30 kips
                                                 13
                    and the shear delivered to the column web is F   V   229   30   199
                                                               f   s
                    kips. Since 199 kips > 185 kips, a doubler (or doublers) is still indicated.
                    If some panel zone deformation is acceptable, the AISC Specification
                    Section J10.6, Formula J10-11 or J10-12, contains an extra term which
                    increases the panel zone strength. The term is

                                       2                     2
                                   3b fc t fc  3 3 14.6 3 0.780
                                          5                    5 0.184
                                  d b d c t wc  21.0 3 14.2 3 0.485



                 Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)
                             Copyright © 2009 The McGraw-Hill Companies. All rights reserved.
                              Any use is subject to the Terms of Use as given at the website.