Page 167 - Handbook of Structural Steel Connection Design and Details
P. 167

Design of Connections for Axial, Moment, and Shear Forces

                    152    Chapter Two


































                    Figure 2.55 Extended Single Plate Connection.



                      Example––Extended Single Plate Tab Connection (See Fig. 2.55)
                      Inelastic bolt design. (From AISC 13th Edition Manual Table 7-7)
                                C   4.34
                               R   C    r
                                n         n
                                    4.34   35.3
                                    153   150 kips, ok

                        Bearing / Tearout On Controlling Element
                        Bearing / Tearout Does Not Control
                      Maximum Plate Thickness—due to the uncertainty related to the dis-
                    tribution of moments through the connection the plate and bolt group
                    are sized such that yielding in the plate will preclude fracture of the bolts
                    by redistributing the moments. It should be noted that this check uses
                    the nominal bolt capacity without a factor of safety and discounts the
                    20% reduction in bolt shear strength assumed in the Specification to
                    account for uneven force distribution in end-loaded connections. Since
                    this is essentially a ductility check and not a strength limit state, this
                    should not be considered a violation of the Specification.




                 Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)
                             Copyright © 2009 The McGraw-Hill Companies. All rights reserved.
                              Any use is subject to the Terms of Use as given at the website.
   162   163   164   165   166   167   168   169   170   171   172