Design of Connections for Axial, Moment, and Shear Forces
Design of Connections for Axial, Moment, and Shear Forces 153
Calculating the bolt value as described above:
r n s1.25d 35.3s1.25d
v
R 5 5 5 58.8 kips/bolt
n
v 0.75
M R C
n
58.8 44.5
2620 kips-in
6M 6s2620d
t max 5 2 5 2 5 0.546 $ 0.5 ok
F L s50ds24d
y
Gross shear and bending interaction on plate
First the plate is checked to ensure buckling does not control
L 2F y
l 5
L 2
t p 47,500 1 112,000a b
B 2a
24250
5 5 0.683 # 0.7
24 2
0.5 47,500 1 112,000c d
B 2s9d
Therefore, buckling does not control
F y t p L
R 5
n
a 2
16a b 1 2.25
B L
0.9s50ds0.5ds24d
5 5 255 kips $ 150 kips , ok
9 2
16a b 1 2.25
B 24
Net shear on plate
1
R 5 0.6F t cL 2 na 1 bd
b
y p
n
16
5 s0.75d0.6s65ds0.5d[24 2 8s1.125d] 5 219 kips $ 150 kips , ok
5
Weld size required – Note the weld size is required to be / of the
8
plate thickness to ensure that the plate yields and redistributes load
prior to weld fracture.
5 5
5
w 5 t p 5 s0.5d 5 0.3125 use /
weld
16
8 8
Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)