Page 430 - High Power Laser Handbook
P. 430

3v Laser                                                                                                       The National Ignition Facility Laser    399
                  Parameter      96 Beam PCC  Achieved Values  Shot Number
                  Pulse energy   ≥500 kJ      542kJ for 96 beams  N081219-002-999
                                              564kJ for 96 beams  N081221-003-999
                  Peak power     ≥200 TW      215 TW Peak      N081222-001-999
                                              205 TW Average   N081221-003-999
                                              over 2 ns
                  Wavelength     O.35 μm      O.35 μm          Entire campaign
                  Positioning    <100 μm RMS  64 μm RMS        N090114-002-999
                  accuracy
                  Pulse duration  Up to 20 ns  Up to 20.9 ns   N081222-002-999
                  Pulse dynamic   ≥25:1       >90:1            N081221-003-999
                  range
                  Pulse spot     ≤600 μm      500 TW in 330 μm  N060329-002-999
                  size (without               530 TW in 600 μm  (B318 on PDS)
                  smoothing)
                                                  8
                                    8
                  Prepulse power  <10  W/cm 2  <10  W/cm ,     Many
                                                        2
                                              Measure at PAM
                                              or 1ω main laser
                                              output, analysis
                                              to TCC
                  Cycle time     8 hours max   5:10, 6:02,     Shortest:
                                 between full   and 6:12 hours   N081218-003-999
                                 system shots  between shots   N081219-001-999
                                              during campaign

                 Table 14.8  Comparison of 96-Beam Performance with PCC Requirements


                                                               CCD counts
                                                 17% contour            4
                                                 P2/P0 = 14 ± 2%     3 10
                                                 P4/P0 = 1 ± 6%
                                50
                                                                     2 10 4
                               Y (µm)  0                             10 4




                               −50
                                                                     0
                                            1.05 MJ N091204-001-999
                                       −50      0       50
                                              X (µm)
                      Figure 14.36  X-ray framing camera image of an imploded 2-mm-diameter gas-
                      filled capsule. NIF scientists have demonstrated the ability to achieve high
                      capsule compression while controlling the imploded-configuration symmetry.
                 398
   425   426   427   428   429   430   431   432   433   434   435