                                                      Notes:
                                                       1. Surfaces marked G to  be ground and
                                                         polished.
                                                       2.  Diametral clearance C to be 0.001  i
                                                         0.0005 inch.
                                                       3.  Location H to  accept  30,000  psi hy-
                                                         draulic fitting.
                                                       4.  O-rings to be Buna-N 90 durometer.
                                                       5.  Drill 4  spanner  wrench  holes  on  cir-
                                                         cumference B.
                                                       6.  Outer  cup  A  to  have wall  thickness
                                                         consistent with 30,000 psi pressure re-
                                                         tention requirement.
                                                       7. Outer cup A to be AiSl 4340 steel.








                           Figure 3-94. Hydraulic pull-off fixture for tapered-bore coupling hubs.









                                                     Notes:
                                                       1.  Surfaces marked G to be ground and
                                                         polished.
                                                       2.  Diametral clearance C to be 0.001  2
                                                         0.0005 inch.
                                                       3.  Location H to  accept  30,000  psi  hy-
                                                         draulic fitting.
                                                       4.  O-rings  to be Buna-N 90 durometer.
                                                       5. Machine,wrench flat at 8.
                                                       6.  Outer  cup  A  to  have  wall  thickness
                                                         consistent with 30,000 psi pressure re-
                                                         tention requirement.
                                                       7.  Outer cup A to be AIS1 4340 steel.











                          Figure 3-95. Hydraulic mounting fixture for tapered-bore coupling hubs.