Page 153 - Pipeline Rules of Thumb Handbook
P. 153

140     Pipeline Rules of Thumb Handbook


























































                                    Figure 10. Daily Operation Report. Courtesy Milbar Hydrotest.








                                                       APPENDIX A



         Volume of water required to fill test section


                          2
         V =  L ¥ (3 1416  ¥  d 4 ) ¥ 12 231             (1)   Where: L = Length of test section, feet.
                  .
                                                                      d = Inside diameter of pipe, inches.
                      2
         V = 0.0408 ¥ d ¥ L                                           V = Gallons required to fill @ 0psig.