Page 153 - Pipeline Rules of Thumb Handbook
P. 153
140 Pipeline Rules of Thumb Handbook
Figure 10. Daily Operation Report. Courtesy Milbar Hydrotest.
APPENDIX A
Volume of water required to fill test section
2
V = L ¥ (3 1416 ¥ d 4 ) ¥ 12 231 (1) Where: L = Length of test section, feet.
.
d = Inside diameter of pipe, inches.
2
V = 0.0408 ¥ d ¥ L V = Gallons required to fill @ 0psig.