234    Reciprocating  Compressors:  Operation and Maintenance





























         FtGURE  4-6.  Schematic  illustrating  the two components  of an electronic web
         deflection  measuring system  (Source: Indikon Company, Inc., Somerville, Mass.),


         CAUSES OF WEB   DEFLECTION


           Several  factors  may  contribute  to  web  deflection  and  must  be  exam-
         ined  before,  during, and after  taking  web deflection  measurement.  Some
         of these factors include, but are not limited to:

           • compressor  support—grouting  conditions
           • anchor bolts—torque value
           • sole plate and chock adjustment and torque
           • shim packing,  alignment  of  any  compressors,  distance  pieces, and
             cold supports
           • rod run-out, proper  frame alignment
           • main bearings, clearances
           • good  lubrication, oil analysis
           • compressor load,  overload
           • soil conditions, fill


           All  of these  factors,  either  solely,  together,  or in any combination,  will
         contribute to web deflection and must be addressed  and corrected  before