366    Reciprocating  Compressors:  Operation  and  Maintenance
























         FIGURE  6-8.  75% of load. Acceleration level = 5.8 g. (Source:  Bently-Nevada
         Corporation,  Minden,  Nevada).

























         FIGURE  6-9.  100% of load. Acceleration level = 7.8 g. (Source:  Bendy-Neva-
         da  Corporation,  Minden,  Nevada).



           The  inspection  revealed a loose locknut on one of the piston  rods.  This
         locknut locks the piston to the piston  rod;  the nut is secured  to a  specified
         torque. The  nut had loosened,  allowing the piston  to become  loose  on the
         piston  rod. This was the source of the hitting that  was seen  on the  oscillo-
   376   377   378   379   380   381   382   383   384   385   386