396   Reciprocating Compressors: Operation and Maintenance


         from  the  residual heat  in the cylinder and  the varying compressibility of
         the gas. A better formula  has been developed as shown in Equation A-10:


              = 100-L-Cl%-                                          (A-10)
                                Z 2  P,


         where L is taken from  Figure A-3.


         Basic Equations

            Reciprocating compressor calculations are performed in stages. There-
         fore,  the number of stages must be determined first. This is based  on lim-



























                                                      NON-LUBRICATED
                                                   COMPRESSORS, MULTIPLY
                                                   THE LOSS CORRECTION
                                                   BY  2.



                       l.O      2.O     3.O    4.O      5.O
                                  RATIO Or COMPRESSION
         FIGURE  A-3.  Loss  correction  "L"  at  different  compression  ratios and suction
         pressures.