Page 34 - The Engineering Guide to LEED-New Construction Sustainable Construction for Engineers
P. 34

Intr oduction    17


                                                                    Possible  Tentative
         Yes   ?  No                                                Points   Points
         Y             SSp1: Construction Activity Pollution Prevention  Required  −
                       SSc1: Site Selection                         1
                       SSc2: Development Density & Community Connectivity  5
                       SSc3: Brownfield Redevelopment               1
                       SSc4.1: Alternative Transportation—Public    6
                       Transportation Access
                       SSc4.2: Alternative Transportation—Bicycle Storage   1
                       and Changing Rooms
                       SSc4.3: Alternative Transportation—Low-Emitting &   3
                       Fuel-Efficient Vehicles
                       SSc4.4: Alternative Transportation—Parking Capacity  2
                       SSc5.1: Site Development—Protect or Restore Habitat  1
                       SSc5.2: Site Development—Maximize Open Space  1
                       SSc6.1: Stormwater Design—Quantity Control   1
                       SSc6.2: Stormwater Design—Quality Control    1
                       SSc7.1: Heat Island Effect—Non-roof          1
                       SSc7.2: Heat Island Effect—roof              1
                       SSc8: Light Pollution Reduction              1
         Y             WEp1: Water Use Reduction Required           Required  −
                       WEc1: Water Efficient Landscaping            2–4
                       [2 pts-50%; 4 pts-100%]
                       WEc2: Innovative Wastewater Technologies     2
                       WEc3: Water Use Reduction                    2–4
                       [2 pts-30%; 3 pts-35%; 4 pts-40%]
         Y             EAp1: Fundamental Commissioning of Building Energy  Required  −
                       Systems
         Y             EAp2: Minimum Energy Performance             Required  −
         Y             EAp3: Fundamental Refrigerant Management     Required  −
                       EAc1: Optimize Energy Performance – [New (Existing)]  1–19
                       [1 pt-12%(8%); 2 pts-14%(10%); 3 pts-16%(12%);
                       4 pts-18%(14%); 5 pts-20%(16%); 6 pts-22%(18%);
                       7 pts-24%(20%); 8 pts-26%(22%); 9 pts-28%(24%);
                       10 pts-30%(26%); 11 pts-32%(28%); 12 pts-34%(30%);
                       13 pts-36%(32%); 14 pts-38%(34%); 15 pts-40%(36%);
                       16 pts-42%(38%); 17 pts-44%(40%); 18 pts-46%(42%);
                       19 pts-48%(44%)]
                       EAc2: On-site Renewable Energy               1–7
                       [1 pt-1%,2  pts-3%; 3 pts-5%; 4 pts-7%; 5 pts-9%; 6
                       pts-11%; 7 pts-13%]

        TABLE 1.2.4  Blank Example LEED 2009 Checklist for Columbia, SC 29201 (Sheet 1) (Continued)
   29   30   31   32   33   34   35   36   37   38   39