FLUID FLOW
                                                  INPUT




                                                                    PROXIMITY
                                                                    SENSOR  COUNTER
                                                 (a)                                 OUTPUT

                                                                           COUNTER
                                                                                     OUTPUT
                                                                                   PROXIMITY
                                                                                   SENSOR



                                                                               PADDLE WHEEL
                                                                     FLUID FLOW
                                                                 INPUT




                                                 (b)

                                                                                        OUTPUT
                                                                                  ANGULAR VELOCITY
                                                                                  SENSOR


                                                                                   DRIVE GEAR
                                                           FLUID FLOW
                                                       INPUT

                                                                                  IDLER GEAR


                                                 (c)


                                 FIGURE 45.10  Fluid power flowmeters: (a) turbine flowmeter, (b) paddle wheel flowmeter, (c) gear motor
                                 flowmeter.


                                     • Ultrasound (Fig. 45.11)
                                     •  Vortex shedding (Fig. 45.12)
                                     •  Thermal anemometer (Fig. 45.13)
                                     •  Electromagnetic (Fig. 45.14)
                                     •  Rotameter (variable-area in-line flowmeter) (Fig. 45.15)
                                   Differential pressure flowmeters are suited to high- and moderate-velocity flow of gas and clean, low-
                                 viscosity liquids. Venturi flowmeters [Fig. 45.9(a)] are the most accurate, but they are large and expensive.
                                 Orifice flowmeters [Fig. 45.9(b)] are smaller, less expensive, and much less accurate than venturi flowmeters.