98                    Thermal Hydraulics Aspects of Liquid Metal Cooled Nuclear Reactors










































         Fig. 3.2.15 View of the top flange of the main vessel, the steam generator is highlighted in blue.




         l  The steam chamber consisting of branch 150 that allows the steam collection from the
            seven tubes.
         l  The LBE equivalent channel (pipe 403) that simulates the shell side of steam generator has
            been simulated with an equivalent channel.
         The time-dependent volume (TMDPVOL) 401 sets the LBE inlet temperature, and
         TMDPJUN 402 fixes the LBE mass flow rate, while the TMDPVOL 405 represents
         the LBE outlet.
            The hot water at the steam generator inlet is heated by a heat source that simulates
         the preheater component installed in the secondary loop upstream the steam generator;
         the water pressure in the entire line is controlled by a VALVE component positioned
         downstream the steam generator. A TMDPVOL at the end of the discharge line
         defines the environment conditions of the air for the steam discharge at 10°C and
         atmospheric pressure.