Page 158 - Tunable Lasers Handbook
P. 158

138     Charles Freed

                    TABLE  1 1  Frequency Differences in kHz between Results Published in
                    References [37] and [38]

                            ~~
                            C02 laser
                        Band     Transition              i5C1607    12CIX0,   13~180~
                                                        -10.2       86.0      -72.9
                                               10.7       6.9        9.1       3.4
                                                6.5       6.0        6.4       6.3
                                                6.1       5.6        7.5       9.6
                                                7.5       7.0        5.2       10.8
                                                4.9       8.1        4.1       7.5
                                                3.0       9.0        1.9       5.4
                                  vu = v(0)     3.0       9.2        5.0       5.1
                                                3.0       9.3        5.1        5.1
                                                4.8       8.7        5.3        7.1
                                                5.3       5.8        3.9        7.7
                                                2.8       5.6        3.5        4.9
                                                5.9       8.8        8.9        6.3
                                               -3.1      -50.1      31.3       -9.7
                                             -129.1      -23.8      85.1     -119.1

                                   P(60)       71.3       -0.1       3.5      -14.4
                                   P(50)        5.8       8.9        3.1        6.0
                                   P(40)        4.4       2.7        3.0        3.3
                                   P(30j        4.6       1.1        1.1        6.3
                                   P(20)        2.9       1.7        3.5        8.0
                                   P(l0j        3.6       1.7        1.5        5.0
                                   P(3j         4.8       4.3        1 .o       3.2
                                  vo = v (0)    5.0       4.4        1.2        3.1
                                                5.0       1.5        1.3        3.1
                                                3.6       5.3        2.6        4.7
                                                0.7       4.5        2.1        1.8
                                                1  .o     4.4        0.3        1.7
                                                3.9        5.5       5.5        3.4
                                                8.2      -48.2      25.5       -7.1
                                               -52.2    -296.2      33.0     -128.9


                    used in the experiment was filled with 2 Torr CO,,  2 Torr N,,  and 7 Torr He par-
                    tial pressures, and the fill pressure of the internal CO,  absorption cell was 0.02
                    Torr. Thus the effective pressure shift appeared to be about 330 kHz/l 1 Torr - 30
   153   154   155   156   157   158   159   160   161   162   163