Page 149 - Well Control for Completions and Interventions
P. 149

Well Control Surface Equipment                               141









                                                              Ram preventer
                             Ram preventer
                             Ram preventer
                                                                      Drilling spool

                                    Drilling spool            Ram preventer
                                                                       Kill line
                              Wellhead
                                                               Wellhead


              Figure 4.1 Blow out preventer configuration for pressure up to 2000 psi.








                                                             Annular preventer


                           Annular preventer
                                                            Ram preventer

                          Ram preventer
                                                                     Drilling spool
                          Ram preventer

                              Drilling spool                Ram preventer
                          Wellhead                          Wellhead



              Figure 4.2 Blow out preventer configuration for 3000 and 5000 psi working
              pressure.

                 • The kill and choke lines can be connected to the inlet of the ram
                   BOP or to a drilling spool.
                 • The kill and choke line must be at least 2 in. nominal diameter.
                 • If used, the drilling spool can be positioned between the BOP
                   rams or below the lower ram. It must have two side outlets of at
                   least 2 in. nominal diameter.