Page 117 - Fluid Power Engineering
P. 117

W i nd Measurement    95


                               Data Validation Flowchart



































              FIGURE 6-13 Flowchart of data management. (Source: Wind Resource
              Assessment Handbook: Fundamentals for Conducting a Successful Monitoring
              Program, April 1997, created by AWS Scientific, Inc. on behalf of the National
              Renewable Energy Laboratory, http://www.nrel.gov/wind/pdfs/22223.pdf.)

                    Import the data

                    Validate the data to create valid data files

                    Process the data to compute derived quantities like shear, en-

                    ergy density, and others
                    Generate reports.

              The first data management step arises during setup of the tower and
              data server. The first step is to check the sensor parameters and units
              of measure of data arriving at the server against parameters supplied
              by the sensor manufacturer. This will check for any data entry errors
              when entering parameters into the data logger. The next check is to
              compare the first few hours of measured data against wind data from
              neighboring airport or weather station. This will check for defective
              sensors, improper mounting of sensors, and incorrect orientation of
              wind vane sensor.