Page 518 - Advanced Design Examples of Seismic Retrofit of Structures
P. 518

Index 461


               without horizontal ties, 72–73  H
             Flexural strength                Historic adobe earthquake damage typologies,
               of beams, 214–215, 214t            399, 400–401t
               of columns                     Horizontal distribution of demand forces, 56–73
                and axial strength, 215–217   Horizontal ties, 51
                and shear strength, 215, 216t
             Floor-to-wall connection, 412f   I
             Force-controlled actions, 74
               acceptance criteria            Incremental seismic rehabilitation (ISR), 89–90
                linear static procedure, 310  In-plane bed-joint sliding strength of URM
                nonlinear static procedure, 311   walls and piers, 76–77
                                              In-plane rocking strength of URM walls and
               capacity forces, 300
                                                  piers, 75–76
             Foundations
                                              Instruction for Seismic Rehabilitation of
               control and design, 172–180
                                                  Existing Buildings, 43–45
               control of structural adequacy under
                                              Internal FRP bars, 395–396, 398f
                  gravitational loads
                                              Intersecting walls, 21
                flexural behavior of foundation section,
                                              Iranian adobe buildings
                  177, 177f
                                               characteristics, 422–431
                loads combinations, 175
                                               comparison of test results and field
                soil pressure control, 175
                                                  observations, 448–455
                soil settlement control, 175–176
                                               experimental studies, 432–447
               plan and observations, 128f
                                               shaking table tests, 437–442, 446–447
               retrofit design, 177–180, 186f
                                               static cyclic tests, 432–437, 443–446
                connection bars details, 185f
                                               survey of damage, 431–432
                controlling soil pressure, 177–179
                                              Iranian Code of Practice for Seismic Resistant
                flexural capacity, 181f
                                                  Design of Buildings, 36, 50
                negative moments, 182f
                                              Irregularity, 43–49
                new foundation design, 180
                                               steel frame building
                positive moments, 183f
                                                 elimination/reduction, 331
                reinforcement details, 184f
                                                 requirements, 285–287, 288–289t
               soil design parameters
                foundation uplift, 331, 334f
                geometrical characteristics, 328,  J
                  329–330f                    Jack-arch diaphragm, 40–41
                geotechnical tests and field observations,  Jack-arch roofs, 35–36
                  328, 328t
                prescriptive expected bearing capacity,
                  325–328                     L
                required foundation reinforcement, 331,  Linear static procedure
                  335f                         acceptance criteria
               soil pressure                     deformation-controlled actions, 308–310,
                of main building, 331, 332–333f   309t, 312t
                of sports building, 331, 335f    force-controlled actions, 310
             Friction shear capacity, of shear walls,  capacity forces
                  173–174t                       beams, 303–306, 305–306t
                                                 columns, 306–307, 307t
             G                                 steel frame building with masonry
             Gable-end walls, 21                  infill walls
             Getty Seismic Adobe Project (GSAP) initiative,  base shear, 228–231
                  398–399                        deformation-controlled actions, 232–233
               small-scale model buildings, 404, 406t  demand capacity ratios, 231
             Grout injection, 90, 91f,92–93      force-controlled actions, 233–234
   513   514   515   516   517   518   519   520   521   522   523